Roundabout homolog 2 (ROBO2)

Links to databases

Roundabout homolog 2 (ROBO2) is a member of the large immunoglobulin superfamily of proteins and functions as a receptor for SLIT2, playing a significant role in neural development through axonal navigation at the ventral midline of the neural tube and projection of axons to different regions. Via its interaction with SLIT2, ROBO2 is essential for midline guidance in the forebrain by acting as repulsive signal preventing inappropriate midline crossing by axons projecting from the olfactory bulb. In spinal chord development may play a role in guiding commissural axons once they reached the floor plate by modulating the response to netrin.

Sample type

Recommended sample types are human EDTA plasma and serum. A range of additional sample types are compatible with the technology (PEA), including citrate plasma, heparin plasma, cerebrospinal fluid, (CSF), tissue and cell lysates, fine needle biopsis, microdialysis fluid, cell culture media, dried blood spots, synovial fluid, saliva, plaque extract and microvesicles. Please note that protein expression levels are expected to vary in different sample types. Certain assays are differentially affected by interfering substances such as hemolysate. Download any of our Data Validation documents or contact support@olink.com for more information.

NOTE: The calibrator curve below shows the performance of the assay with the estimated sensitivity and dynamic range parameters indicated. These curves are generated during the assay validation process using recombinant antigens. Please note that when analyzing biological samples the data generated will be given in the form of relative quantification (NPX values) and cannot be converted to absolute protein concentrations. For more info about NPX measurements, please visit our FAQ page.

Analytical Measuring Range

    • LOD (pg/mL)
    • 7.63
    • LLOQ (pg/mL)
    • 7.63
    • ULOQ (pg/mL)
    • 31250
    • Hook (pg/mL)
    • 31250
    • Range (logs)
    • 3.6

Calibrator curve generated in multiplex

Roundabout homolog 2 (ROBO2)

Precision

    • Within run precision Coefficient of Variation (CV)
    • 8%
    • Between run precision Coefficient of Variation (CV)
    • 11%

Precision (repeatability) is calculated from linearized NPX values over LOD.