Leucine-rich repeat transmembrane protein FLRT2 (FLRT2)

Links to databases

Leucine-rich repeat transmembrane protein FLRT2 is a member of the fibronectin leucine rich transmembrane protein family, which function in cell adhesion and/or receptor signalling. FLRT2 is expressed in brain as well as in the heart and several other organs, and is involved in fibroblast growth factor-mediated signaling cascades. In the heart, it is required for normal organization of the cardiac basement membrane during embryogenesis, and for normal embryonic epicardium and heart morphogenesis. In the neurology context, FLRT2 functions in cell-cell adhesion, cell migration and axon guidance. It may play a role in the migration of cortical neurons during brain development via its interaction with UNC5D.

Sample type

Recommended sample types are human EDTA plasma and serum. A range of additional sample types are compatible with the technology (PEA), including citrate plasma, heparin plasma, cerebrospinal fluid, (CSF), tissue and cell lysates, fine needle biopsis, microdialysis fluid, cell culture media, dried blood spots, synovial fluid, saliva, plaque extract and microvesicles. Please note that protein expression levels are expected to vary in different sample types. Certain assays are differentially affected by interfering substances such as hemolysate. Download any of our Data Validation documents or contact support@olink.com for more information.

NOTE: The calibrator curve below shows the performance of the assay with the estimated sensitivity and dynamic range parameters indicated. These curves are generated during the assay validation process using recombinant antigens. Please note that when analyzing biological samples the data generated will be given in the form of relative quantification (NPX values) and cannot be converted to absolute protein concentrations. For more info about NPX measurements, please visit our FAQ page.

Analytical Measuring Range

    • LOD (pg/mL)
    • 15.26
    • LLOQ (pg/mL)
    • 15.26
    • ULOQ (pg/mL)
    • 62500
    • Hook (pg/mL)
    • 250000
    • Range (logs)
    • 3.6

Calibrator curve generated in multiplex

Leucine-rich repeat transmembrane protein FLRT2 (FLRT2)

Precision

    • Within run precision Coefficient of Variation (CV)
    • 6%
    • Between run precision Coefficient of Variation (CV)
    • 7%

Precision (repeatability) is calculated from linearized NPX values over LOD.