Mothers against decapentaplegic homolog 5 (MAD homolog 5)

Links to databases

 

Mothers against decapentaplegic homolog 5 (MADH5) also known as SMAD5, is named after its Drosophila homolog and is a member of the SMAD family of proteins, which are part of the TGFbeta superfamily of transcriptional modulators. MADH5 is activated by bone morphogenetic protein (BMP) type 1 receptor kinase, and modulates the cell signalling pathways that are regulated by BMPs.MADH5 is thought to modulate a TGFbeta-dependent pathway that inhibits hematopoietic progenitor cells.

Sample type

Recommended sample types are human EDTA plasma and serum. A range of additional sample types are compatible with the technology (PEA), including citrate plasma, heparin plasma, cerebrospinal fluid, (CSF), tissue and cell lysates, fine needle biopsis, microdialysis fluid, cell culture media, dried blood spots, synovial fluid, saliva, plaque extract and microvesicles. Please note that protein expression levels are expected to vary in different sample types. Certain assays are differentially affected by interfering substances such as hemolysate. Download any of our Data Validation documents or contact support@olink.com for more information.

NOTE: The calibrator curve below shows the performance of the assay with the estimated sensitivity and dynamic range parameters indicated. These curves are generated during the assay validation process using recombinant antigens. Please note that when analyzing biological samples the data generated will be given in the form of relative quantification (NPX values) and cannot be converted to absolute protein concentrations. For more info about NPX measurements, please visit our FAQ page.

Analytical Measuring Range

    • LOD (pg/mL)
    • 30.52
    • LLOQ (pg/mL)
    • 30.52
    • ULOQ (pg/mL)
    • 62500
    • Hook (pg/mL)
    • 125000
    • Range (logs)
    • 3.3

Calibrator curve generated in multiplex

Mothers against decapentaplegic homolog 5 (MAD homolog 5)

Precision

    • Within run precision Coefficient of Variation (CV)
    • 7%
    • Between run precision Coefficient of Variation (CV)
    • 13%

Precision (repeatability) is calculated from linearized NPX values over LOD.

Biomarker Validation Data

Additional validation data, as well as a more detailed description of how the Olink panels are quality controlled can be found in our Data Validation documents. To download or to learn more go to the Data Validation page.

View all Oncology II panel biomarkers >

View all biomarkers >